Customization: | Available |
---|---|
Task: | Program |
Structure: | Closed-Loop |
Still deciding? Get samples of US$ 18.9/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | MP-S1 plus |
Main technical data | |
.Start type | Direct on line |
. Qty of controlled pump | Single pump |
. Rated input voltage: | AC220V-240V Single phase 50HZ/ 60HZ |
. Rated output power: | 0.37kw-2.2kw (0.5hp-3hp) |
.Capacitor: | Reserved space for installing start capacitor |
Product function |
Over load protection Pump stalled protection Dry run protection with sensor free Under voltage protection Over voltage protection |
Application & Control characteristic |
Control and protect universal pump Adopting liquid probe or float switch or pressure switch to control pump start and stop •Applied for water supply by liquid level control through float switch or liquid probe •Applied for booster by pressure control through pressure switch and pressure tank •Applied for drainage by liquid level control through float switch or liquid probe |
Other features |
Push button calibration Memory funcion when power off & recovery LCD screen displaying pump running status Signal transmission distance up to 200m |
Main installation data | |
Working temperature Working humidity Degree of protection Install position Unit dimension (L x W x H) |
-25ºC-- +55ºC 20%--90%RH, no drips concreted IP54 Wall mounting 180 x 150 x 70 mm |
General details | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Main introduction |
SPLC is an easy to use, programmable controlling & protection device for pump factory, pump dealer / distributor etc to assemble the duplex pump control cabinet by using SPLC , MCB, AC contactor and other components. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Model | SPLC-3/BOOSTER TYPE | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Main technical data | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Start type | DOL / STAR-DELTA / SOFT START / AUTO COUPLING | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Qty of controlled pump | Triplex pump | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated input voltage | AC380V Three Phase 50HZ/ 60HZ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rate output power | 0.75kw(1hp)-250kw(335hp)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Protection Function |
Overload protection ensures operational safety. Pump stalled protection guards against mechanical failure. Sensor-free dry run protection prevents damage when no liquid is present. Under voltage protection for consistent performance. Over voltage protection to avoid electrical surges. Open phase protection maintains energy balance. Phase unbalance protection to secure motor function. Phase reversal protection for correct rotation direction. Pump shaft anti-rust protection extends equipment life. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Application & Control Characteristic |
Comprehensive control and protection solutions for triplex pump systems. Utilizes pressure switches or transmitters for pump start/stop control. Ideal for water supply systems with pressure-based control, using pressure switches or transmitters. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Other Features | Experience the convenience of a versatile DIP switch (5P) designed to easily adjust and configure different output power settings, ensuring optimal performance tailored to your unique needs. Harness the flexibility of a practical DIP switch (3P), expertly crafted for seamless application setting adjustments, empowering you to customize configurations with ease. Utilize the adaptable DIP switch (2P) to effortlessly modify various starting type settings, providing you with the ultimate control over your pump's initial operations. Access an innovative feature that displays the last five fault records of your pump, delivering critical insights into your system's performance and maintenance needs. Effortlessly monitor your pump's operational efficiency with a clear display of its accumulative running time, ensuring informed and proactive maintenance decisions. Introducing the dry contact point (BA port), a pivotal component for streamlined connectivity and enhanced system integration. Presenting the RS485 port, an essential feature offering robust communication capabilities for seamless data exchange and control. Opt for our optional user remote monitor, providing unparalleled convenience and the ability to oversee pump operations from a distance. Benefit from our LCD screen's locked function in auto state, securing settings and operations to prevent unauthorized changes and ensuring reliable performance. Enhance your system's connectivity with an optional WiFi module, enabling remote access and control for a superior user experience. Our intuitive LCD screen vividly displays the pump's running status, delivering real-time information for effective monitoring and management. |