Customization: | Available |
---|---|
Task: | Program |
Structure: | Closed-Loop |
Still deciding? Get samples of US$ 90/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application | Design for reverse osmosis water purification unit , DOL |
Model | RO 2-2 |
Rated input voltage | AC220V-240V Single phase 50HZ/ 60HZ |
Rated input voltage for RAW Water Pump(RWP) High Pressure Pump(HPP) Solenoid valve |
Single phase(0.37-2.2kw) Single phase(0.37-2.2kw) |
Normally closed type(AC 220V.) | |
Protection function |
Over load protection Pump stalled protection Dry run protection Under voltage protection Over voltage protection Open phase protection |
Control characteristic |
Having the complete operating logic of the process pre-programmed . Present terminal port for Pressure switch(LPS /HPS), Present terminal port for Level senor in products tanker , Present terminal port for Float switch in raw water tanker Present terminal port for 2 dosing pumps,1 electrical meter . Controlling the 4 outputs: Raw water pump(RWP), High pressure pump(HPP) The flushing solenoid valve . No-Power Contact for Alarm |
Other features |
Pump accumulative running time displaying Pump five faults record displaying Menu opening for parameter adjustment Push button calibration Memory function when power off & recovery RS485 Communication |
Main installation data | |
Working temperature | -25ºC-- +55ºC |
Working humidity | 20%--90%RH, no drips concreted |
Degree of protection | IP54 |
Install position | Wall mounting |
Unit dimension (L x W x H) | 310*220*120mm |